• product_banner_01

Imikhiqizo

I-LIMEE TECH: Intengo yokuvula/Ukusebenza nge-100GE Layer3 POE Switches

Izici Eziyinhloko:

48*10GE(SFP+), 2*40GE kanye ne-4*100GE(QSFP28)

Amandla okucubungula ukushintshana okuqinile futhi azinzile

I-IPv4/IPv6 imisebenzi yomzila omile

I-RIP/OSPF/RIPng/OSPFv3/PIM namanye amaphrothokholi omzila

Isixhumanisi se-VRRP/ERPS/MSTP/FlexLink/MonitorLink kanye namaphrothokholi angasebenzi enethiwekhi

Indlela yokuhlunga yokuvikela ye-ACL futhi inikeze imisebenzi yokulawula ukuphepha ngokusekelwe ku-MAC, IP, imbobo ye-L4 kanye nezinga lembobo

Umsebenzi wokuhlaziya isibuko samachweba amaningi, Ukuhlaziywa kwesibuko okusekelwe ekugelezeni kwesevisi

I-O&M : Iwebhu/SNMP/CLI/Telnet/SSHv2


IZIMALI ZOMKHIQIZO

AMA-PARAMETER

Omaka bomkhiqizo

I-LIMEE TECH: Intengo yokuvula/Ukusebenza nge-100GE Layer3 POE Switches,
,

Izici eziyinhloko

I-S5354XC isendlalelo sesi-3 sokushintsha komfula sifakwe 48 x 10GE + 2 x 40GE + 4 x 100GE.Ihlinzeka ngomsebenzi ohamba phambili wokonga amandla kanye nokushintsha kokufinyelela okuhlakaniphile kwesizukulwane esilandelayo kumanethiwekhi abahlali benkampani yenethiwekhi namanethiwekhi ebhizinisi.Isofthiwe yomkhiqizo inothile kakhulu emisebenzini, isebenzisa iphrothokholi yomzila yezendlalelo ezintathu, ukuphathwa okulula, ukufakwa okuguquguqukayo, kungasetshenziswa ekuqapheni ukuthunyelwa kwesistimu, ukuphathwa kokulawula kanye nezinsizakalo ezingenazintambo nezinye izinhlelo zokusebenza.Umkhawulokudonsa wokudlulisa kanye namandla okudlulisela phambili makhulu, ahlangabezana nezidingo zezikhungo zedatha kumanethiwekhi ayinhloko kanye namanethiwekhi omgogodla.Ezimweni ezidinga isimo sezulu, amazinga okushisa asukela ku -40 ° C kuya ku-70 ° C.

FAQ

Q1: Iyini i-MOQ yakho ye-ONT ne-OLT?

Nge-oda yeqoqo, i-ONT amayunithi angama-2000, i-OLT amayunithi angama-50.Amacala akhethekile, singaxoxa.

Q2: Yimaphi amazwe nezifunda imikhiqizo ethunyelwe kuzo?

A: Imikhiqizo yethu ithengiswa kakhulu eLatin America, e-Asia, e-Afrika naseYurophu.

Q3: Kuthiwani ngesevisi yakho yobuchwepheshe?

IMP: Noma yiziphi izinkinga zobuchwepheshe, sinonjiniyela ongakusiza uxazulule ngomhlahlandlela wesilawuli kude.

Q4: Iyini izinga lakho le-QC?

ukulawulwa kwekhwalithi okungenayo (IQC), ukuhlolwa kokukhiqiza, ukuhlolwa kwesampula ngaphambi kokuthunyelwa.

Esikhathini sanamuhla esisheshayo sedijithali, amabhizinisi nezinhlangano kufanele zizivumelanise ngokushesha ukuze zihlangabezane nezidingo zokudluliswa kwedatha ngesivinini esiphezulu nengqalasizinda yenethiwekhi.Mayelana nezixazululo zenethiwekhi, ukuhlanganiswa kobuchwepheshe obusezingeni eliphezulu obufana nezivumelwano ze-40GE kanye ne-100GE Layer 3 kuya ngokuya kubaluleke kakhulu.Ukuhlanganisa izinzuzo ze-PoE (Amandla phezu kwe-Ethernet) namandla emisebenzi eminingi, lezi zinguquko zinikeza isixazululo sako konke esilinganisa ukusebenza nokusebenza kahle.

Ngokusebenzisa amandla okushintshwa kwemisebenzi eminingi, amabhizinisi angakwazi ukuthuthukisa ukusebenza kwenethiwekhi yawo kuyilapho ehlisa izindleko zokusebenza.Lezi zinguquko zisekela izivumelwano ze-40GE kanye ne-100GE Layer 3 zokudlulisa idatha ngokushesha okukhulu, okuvumela amabhizinisi amakhulu ukuthi asingathe ithrafikhi yenethiwekhi edingeka kakhulu.Ukwengeza, ngokuhlanganiswa okungenamthungo kobuchwepheshe be-PoE, bangaletha amandla ngokuqondile kumadivayisi axhunyiwe, baqede isidingo sezintambo ezengeziwe futhi benze ukuphathwa kwekhebula kube nomoya oshisayo.

Isixazululo esingabizi kakhulu:
Ingqalasizinda yenethiwekhi evamile idinga ukushintshwa okuhlukene ukuze yenze imisebenzi ehlukene, engagcini nje ngokukhuphula inkimbinkimbi kodwa futhi inyuse kakhulu izindleko.Kodwa-ke, ukuvela kokushintshwa kwemisebenzi eminingi kuyishintshe ngokuphelele imithetho yomdlalo.Ngokuhlanganisa imisebenzi ehlukahlukene ibe isisetshenziswa esisodwa, amabhizinisi manje angakwazi ukuthola ukusebenza okuphezulu kuyilapho enciphisa izindleko zokuphakela nokulungisa.Lokhu kunikeza izinhlangano inkululeko yokutshala imali kwezinye izindawo ezibalulekile zokusebenza kwazo futhi kuqinisekisa imbuyiselo ephezulu ekutshalweni kwezimali.

Ukuphishekela okuqhubekayo kwentuthuko yezobuchwepheshe kudinga ingqalasizinda yenethiwekhi ukuthi ibe ubufakazi besikhathi esizayo.Idizayinelwe kucatshangwa ngokuqina, amaswishi emisebenzi eminingi ahlinzeka ngokuguquguquka nokuqina ukuze kuhlangatshezwane nezidingo ezikhulayo zethrafikhi yenethiwekhi.Kungakhathaliseki ukuthi umdlalo, ukusakaza ividiyo, noma imisebenzi edinga idatha, lezi zinguquko zinikeza isisekelo esinamandla nesiguquguqukayo esingasekela izidingo zenethiwekhi zamanje nezesikhathi esizayo.

Ngemisebenzi yabo emihle kakhulu, amaswishi emisebenzi eminingi asekelwe ku-40GE kanye ne-100GE Layer 3 protocol abe umgogodla wezixazululo zenethiwekhi zanamuhla.Baletha isivinini esingenakuqhathaniswa, ukusebenza kahle kanye nokuphumelela kwezindleko.Ngokuhlanganisa ubuchwepheshe be-PoE nokuhlanganisa imisebenzi eminingi kudivayisi eyodwa, amabhizinisi angakwazi ukuthuthukisa ukusebenza kwawo kwenethiwekhi, anciphise izindleko kanye nobufakazi bokusebenza kwawo esikhathini esizayo.Njengoba isimo sedijithali siqhubeka nokuvela, izinhlangano kufanele zamukele lokhu kuthuthuka ukuze zihlale zincintisana, zisebenza kahle futhi zixhumekile.Ngakho-ke uma ubheke ukuvula amandla wangempela enethiwekhi yakho, yisikhathi sokucabangela ukuthuthukela ekushintsheni okunemisebenzi eminingi.


  • Okwedlule:
  • Olandelayo:

  • Imininingwane Yomkhiqizo

    Ukonga amandla

    Amandla wokulala womugqa we-Ethernet eluhlaza

    Ukushintsha kwe-MAC

    Lungiselela ngokungaguquki ikheli le-MAC

    Ukufunda ikheli le-MAC ngamandla

    Lungiselela isikhathi sokuguga sekheli le-MAC

    Khawulela inombolo yekheli le-MAC elifundiwe

    Ukuhlunga ikheli le-MAC

    Ukulawulwa kokuphepha kwe-IEEE 802.1AE MacSec

    Ukusakaza okuningi

    I-IGMP v1/v2/v3

    I-IGMP Snooping

    I-IGMP Ikhefu Elisheshayo

    I-MVR, isihlungi se-Multicast

    Izinqubomgomo zokusakaza okuningi kanye nemikhawulo yezinombolo zokusakaza okuningi

    I-Multicast traffic iphindaphinda kuwo wonke ama-VLAN

    I-VLAN

    4K VLAN

    GVRP Imisebenzi

    QinQ

    I-VLAN yangasese

    I-Network Redundancy

    I-VRRP

    Ukuvikelwa kwesixhumanisi se-ethernet okuzenzakalelayo kwe-ERPS

    I-MSTP

    I-FlexLink

    I-MonitorLink

    802.1D(STP), 802.1W(RSTP), 802.1S(MSTP)

    Ukuvikelwa kwe-BPDU, ukuvikelwa kwezimpande, ukuvikelwa kwe-loop

    I-DHCP

    Iseva ye-DHCP

    Ukudluliselwa kwe-DHCP

    Iklayenti le-DHCP

    I-DHCP Snooping

    I-ACL

    Isendlalelo 2, Isendlalelo 3, kanye nama-ACL angu-4

    IPv4, IPv6 ACL

    I-VLAN ACL

    Irutha

    IPV4/IPV6 iphrothokholi yesitaki esikabili

    Ukutholwa komakhelwane be-IPv6, ukutholwa kwePath MTU

    Umzila omile, RIP/RIPng

    OSFPv2/v3,PIM umzila oguquguqukayo

    I-BGP, BFD ye-OSPF

    I-MLD V1/V2, i-MLD iyahlola

    QoS

    Ukuhlukaniswa kwethrafikhi okusekelwe kuzinkambu ezikusihloko sephrothokholi ye-L2/L3/L4

    Umkhawulo wethrafikhi yemoto

    Phawula okubalulekile kwe-802.1P/DSCP

    Ukuhlela ulayini we-SP/WRR/SP+WRR

    Ukwehla komsila kanye nezindlela zokugwema ukuminyana kwe-WRED

    Ukuqapha ithrafikhi kanye nokuma kwethrafikhi

    Isici Sokuphepha

    Ukuqashelwa kwe-ACL kanye nendlela yokuphepha yokuhlunga esekelwe ku-L2/L3/L4

    Ivikela ekuhlaselweni kwe-DDoS, ukuhlasela kwezikhukhula ze-TCP SYN, nokuhlasela kweSikhukhula se-UDP

    Cindezela ukusakaza okuningi, ukusakaza, namaphakethe e-unicast angaziwa

    Ukuhlukaniswa kwechweba

    Ukuphepha kwembobo, imbobo ye-IP+MAC+ yokubophezela

    I-DHCP sooping, i-DHCP option82

    Isitifiketi se-IEEE 802.1x

    Ukuqinisekiswa komsebenzisi okukude kwe-Tacacs+/Radius, ukuqinisekiswa komsebenzisi wendawo

    I-Ethernet OAM 802.3AG (CFM), 802.3AH (EFM) ukutholwa kwesixhumanisi okuhlukahlukene kwe-Ethernet

    Ukwethembeka

    Xhumanisa ukuhlanganisa kumodi emile / ye-LACP

    Ukutholwa kwesixhumanisi sendlela eyodwa ye-UDLD

    I-ERPS

    I-LLDP

    I-Ethernet OAM

    1+1 isipele samandla

    OAM

    Console, Telnet, SSH2.0

    Ukuphatha WEB

    I-SNMP v1/v2/v3

    I-Physical Interface

    I-UNI Port

    48*10GE, SFP+

    I-NNI Port

    2*40GE, QSFP28

    4*100GE, QSFP28

    I-CLI Management port

    RS232, RJ45

    Indawo Yokusebenzela

    Izinga Lokushisa Lokusebenza

    -15℃55℃

    Izinga Lokushisa Lesitoreji

    -40℃70℃

    Umswakama Ohlobene

    10%~90%(Akukho ukufingqa)

    Ukusetshenziswa kwamandla

    Ukunikezwa kwamandla kagesi

    1+1 amandla akabili, amandla e-AC/DC angakhethwa

    Input Power Supply

    I-AC: 90~264V, 47~67Hz;I-DC: -36V~-72V

    Ukusetshenziswa kwamandla

    Umthwalo ogcwele ≤ 180W, awusebenzi ≤ 25W

    Usayizi Wesakhiwo

    Igobolondo lecala

    Igobolondo lensimbi, ukupholisa umoya kanye nokuchithwa kokushisa

    Ubukhulu bekesi

    19 intshi 1U, 440*390*44 (mm)

    Bhala umyalezo wakho lapha futhi usithumelele wona